TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

DL < 280

DL &lt; 280
 
For increasing, move mouse over the picture

Pressure leak detector with air as leak detection medium


TYPES:

DL 50, DL 100, DL 230

OPTIONAL EQUIPMENT:

P: weatherproof housing

FC: filter control

M: digital manometer

Si: service indication (adjustable 1 to 63 months)

(e.g. DL 100 FCMSi)


TANKS:

  • Aboveground
  • Maximum diameter: depending on alarm pressure and density of stored goods, see documentation
  • Test pressure of interstitial space: see documentation
  • Maximum pressure on tank bottom: see documentation
  • Without leak detection liquid in the interstitial space


STORED PRODUCTS:

Water-polluting liquids. The (possible) explosive vapor-air mixtures (also such ones that can arise through the stored/conveyed liquids in contact with air, humidity, condensation or the materials used) must be classifiable into gas group II A to II B as well as in the temperature code T1 to T3.


INSTALLATION:

Outside Ex areas


HOUSING / IP RATE / TEMPERATURE RANGE:

pl-box: plastic box / IP 30 / -0 °C .. +40 °C

ss-box: stainless steel box / IP 66 / -40 °C .. +60 °C


PNEUMATIC CONNECTIONS:

H4+H6: hose connection for polyvinylchloride (PVC) hose 8/4x2mm or 10/6x2mm

QU8/6: quick union for polyamide (PA) hose 8/6x1mm

CF8/6: compression ferrule for copper (CU) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm

ss-CF8/6: compression ferrule for stainless steel (ss) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm


The requirements of the respective documentation must be observed!

  • Articles 1 - 31 of 31
  • Articles 1 - 31 of 31