TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

DLR-P

DLR-P
 
For increasing, move mouse over the picture

Pressure leak detector with integrated pump. Dried air is used as the leak detection medium.

TYPES:

DLR-P 1.1, DLR-P 2.0, DLR-P 2.3, DLR-P 3.0, DLR-P 3.5, DLR-P 4.5

OPTIONAL EQUIPMENT:

P: weatherproof housing

M: digital manometer

Si: service indication (adjustable 1 to 63 months)

(e.g. DLR-P 2.0 PM)

PIPES:

  • Double-walled pipes and fittings made of metal or plastic

CONVEYED PRODUCTS:

Water-polluting liquids with a flash point > 60 °C (for Germany > 55 °C acc. to TRGS and TRBS) where no explosive vapor-air mixtures occur.

For pipes with an impermeable (metallic) inner wall also for liquids with a flash point ≤ 60 °C (for Germany ≤ 55 °C acc. to TRGS and TRBS), e.g. petrol in filling and suction pipes at filling stations.

The conveyed product may not react with the leak detection medium used!

INSTALLATION:

Outside Ex areas

HOUSING / IP RATE / TEMPERATURE RANGE:

DLR-P 1.1 to DLR-P 2.0 within pl-box: plastic box / IP 30 / 0 °C .. +40 °C

DLR-P 1.1 PM to DLR-P 2.0 PM within ss-box: stainless steel box / IP 66 / -40 °C .. +60 °C

DLR-P 3.5 M and DLR-P 4.5 M within ventilated stainless steel box / IP 20 / 0 °C .. +40 °C

PNEUMATIC CONNECTIONS:

QU8/6: quick union for polyamide (PA) hose 8/6x1mm

FU6/4 flared union for copper (CU) pipe 6/4x1 mm

CF8/6: compression ferrule for copper (CU) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm