TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
navigationTree_a_clickedSaves which menu item was clicked at last.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Show
Cookie Name Description
_gaProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.

DLR-G

DLR-G
 
For increasing, move mouse over the picture
Pressure leak detector with re-filling function from a stationary connected nitrogen bottle or a compressed gas network (operating mode C = continuous). With optional function for operating mode I (= interval) without automatic re-filling function.

Operating mode C (formerly S) for aboveground and underground double-walled pipes.

Operating mode I (formerly M) only for applications without temperature variations of more than +/-10 °C (e.g. double-walled pipes installed underground or indoors; no hot media).
With digital manometer (M).

TYPES:
DLR-G 1 M, DLR-G 2 M, DLR-G 3 M and in 1 bar steps up to DLR-G 18 M

OPTIONAL EQUIPMENT:
P: weatherproof housing
Si: service indication (adjustable 1 to 63 months)
LE: remote monitoring LOD with Ethernet module

PIPES:
  • Double-walled sufficiently pressure-resistant pipes and fittings made of metal or plastic in factory or on-site construction

CONVEYED PRODUCTS:
Water-polluting liquids, even with a flash point ≤ 60 °C (for Germany ≤ 55 °C acc. to TRGS and TRBS). The conveyed product may not react with the leak detection medium used!
Examples: petrol, methanol, diesel, chemicals, acids, lyes.

INSTALLATION:
Outside Ex areas

HOUSING / IP RATE / TEMPERATURE RANGE:
pl-box: plastic box / IP 30 / -0 °C .. +40 °C
ss-box: stainless steel box / IP 54 / -40 °C .. +60 °C

PNEUMATIC CONNECTIONS:
FU6/4: flared union for copper (CU) pipe 6/4x1mm
CF8/6: compression ferrule for copper (CU) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm

The requirements of the respective documentation must be observed!