TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

DLR-G

DLR-G
 
For increasing, move mouse over the picture

Pressure leak detector with re-filling function from a stationary connected nitrogen bottle or a compressed gas network (operating mode C = continuous). With optional function for operating mode I (= interval) without automatic re-filling function.

Operating mode C (formerly S) for aboveground and underground double-walled pipes.

Operating mode I (formerly M) only for applications without temperature variations of more than +/-10 °C (e.g. double-walled pipes installed underground or indoors; no hot media).

With digital manometer (M).

TYPES:

DLR-G 1 M, DLR-G 2 M, DLR-G 3 M and in 1 bar steps up to DLR-G 18 M

OPTIONAL EQUIPMENT:

P: weatherproof housing

Si: service indication (adjustable 1 to 63 months)

PIPES:

  • Double-walled sufficiently pressure-resistant pipes and fittings made of metal or plastic in factory or on-site construction

CONVEYED PRODUCTS:

Water-polluting liquids, even with a flash point ≤ 60 °C (for Germany ≤ 55 °C acc. to TRGS and TRBS). The conveyed product may not react with the leak detection medium used!

Examples: petrol, methanol, diesel, chemicals, acids, lyes.

INSTALLATION:

Outside Ex areas

HOUSING / IP RATE / TEMPERATURE RANGE:

pl-box: plastic box / IP 30 / -0 °C .. +40 °C

ss-box: stainless steel box / IP 66 / -40 °C .. +60 °C

PNEUMATIC CONNECTIONS:

FU6/4: flared union for copper (CU) pipe 6/4x1mm

CF8/6: compression ferrule for copper (CU) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm

The requirements of the respective documentation must be observed!