TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

VLR 410 E

VLR 410 E
 
For increasing, move mouse over the picture

Vacuum leak detector with enlarged electronic functions. Additional sensors and solenoid valves can be connected. Solenoid valves in the connection lines protect the leak detector against overpressures, which can affect the leak detector in case of a leak at a > 5 bar pressurized pipe.

TYPES:

VLR 410 E

OPTIONAL EQUIPMENT:

P: weatherproof housing

M: digital manometer

Si: service indication (adjustable 1 to 63 months)

(e.g. VLR 410 EPM)

PIPES:

  • Double-walled approved pipes and hoses

CONVEYED PRODUCTS:

Water-polluting liquids with a flash point > 60 °C (for Germany > 55 °C acc. to TRGS and TRBS) where no explosive vapor-air mixtures occur.

Examples: heating oil, diesel, and according to list of substances or chemical compatibility: chemicals, acids, lyes.

INSTALLATION:

Outside Ex areas

HOUSING / IP RATE / TEMPERATURE RANGE:

pl-box: plastic box / IP 30 / -0 °C .. +40 °C

ss-box: stainless steel box / IP 66 / -40 °C .. +60 °C

PNEUMATIC CONNECTIONS:

CF8/6: compression ferrule for copper (CU) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm

QU8/6: quick union for polyamide (PA) hose 8/6x1mm

FU6/4: flared union for copper (CU) pipe 6/4x1 mm

ss-CF8/6: stainless steel compression ferrule for stainless steel (ss) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm

PVDF8/6: polyvinyldeflourid connection for polyamide (PA) hose 8/6x1mm or polytetrafluoroethylene (PTFE) hose 8/6x1mm

The requirements of the respective documentation must be observed!