TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

VLX .. A-Ex

VLX .. A-Ex
 
For increasing, move mouse over the picture

Vacuum leak detector, partially explosion-proof, for pipes with overpressures up to a maximum of 10 bar

TYPES:

VLX 330 A-Ex

OPTIONAL EQUIPMENT:

Stainless steel box

PIPES:

  • Double-walled sufficiently pressure-resistant pipes and fittings made of metal or plastic in factory or on-site construction

CONVEYED PRODUCTS:

Water-polluting liquids. The (possible) explosive vapor-air mixtures (also such ones that can arise through the stored/conveyed liquids in contact with air, humidity, condensation or the materials used) must be classifiable into gas group II A to II B3 as well as in the temperature code T1 to T3 (T4 on request). Example: petrol.

INSTALLATION:

Leak indicating unit: outside Ex areas, indoors

Leak detector (device category 2): zone 1, preferably outdoors

HOUSING / IP RATE / TEMPERATURE RANGE:

Leak detector: stainless steel box / IP 66 / -20 °C .. +60 °C

leak indicating unit LAE: plastic box / IP 30 / -0 °C .. +40 °C

leak indicating unit LAE 3-8: plastic box / IP 30 / -0 °C .. +40 °C

PRESSURE RESISTANCE (leak detector):

10 bar

PNEUMATIC CONNECTIONS:

QU8/6: quick union for polyamide (PA) hose 8/6x1mm

CF8/6: compression ferrule for copper (CU) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm

ss-CF8/6: Stainless steel compression ferrule for stainless steel (ss) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm

! Mind the plastic pipe's pressure resistance !

The requirements of the respective documentation must be observed!