TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

LDU22

LDU22
 
For increasing, move mouse over the picture

Leak detection unit LDU22 for tanks and pipes at filling stations based on air overpressure.

The standard version is equipped with a green operating light, a red alarm light, a flashing signal lamp on the top of the housing and an acoustic signal and acknowledgement button.

Combined LDU22 display the alarm for tanks and pipes separately.


TYPES:


LDU22 T280 for tanks with diameter <= 2.5 meters and minimum interstitial space test pressure of 400 mbar

LDU22 T330 for tanks with diameter <= 3.0 meters and minimum interstitial space test pressure of 500 mbar

LDU22 P1.1 for pressureless pipes, such as filling and suction lines

LDU22 P2.0 for pressureless pipes, such as filling and suction lines

LDU22 P3.5 for pressure pipes with max. delivery pressure of 2.5 bar


COMBINATIONS:


LDU22 T280 / P1.1

LDU22 T280 / P2.0

LDU22 T280 / P3.5

LDU22 T330 / P1.1

LDU22 T330 / P3.5


OUTFLOWS:


up to 18 underground tanks

up to 32 pipes

combined up to 28 tanks/pipes

only possible in steps of two


TANKS/PIPES:


Tanks with a maximum internal overlay pressure of 500 mbar and a pressure resistance of the interstitial space of 400 or 500 mbar

Suitable pipes with a pressure resistance of the interstitial space of at least 5 bar

The interstitial spaces must not be defined as zone 0.


STORED/CONVEYED PRODUCTS:


Water-polluting liquids. Any explosive vapor-air mixtures that occur (including those that may be created by the stored/conveyed liquid in conjunction with air, humidity, condensate or the materials used) must be classifiable in explosion group II A to II B and temperature class T1 to T3, e.g. gasoline, diesel, AdBlue.


INSTALLATION:


Outside the Ex area or in areas where zone 1 does not exceed a height of 1 meter.


HOUSING / PROTECTION CLASS:


st-box: painted sheet steel housing / IP43

ss-box: Stainless steel housing / IP43


OPTIONS:


MH and FCMH

FC Dry filter monitoring: optical and acoustic alarm signal in case of depletion of dry beads

M Digital pressure display inside the upper part of the housing for more comfortable maintenance

H Heater for temperature range: -40 °C.. +60°C


TEMPERATURE RANGE:


unheated: -10 °C ... +60 °C

heated: -40 °C ... +60 °C


PNEUMATIC CONNECTIONS:


QU8/6: Quick union for polyamide (PA) hose 8/6x1 mm


The requirements from the documentation must be complied with.