TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

VLXE

VLXE
 
For increasing, move mouse over the picture

Ex vacuum leak detector with simple explosion protection, for mounting outside Ex areas, for pressureless tanks for storing e.g. petrol.

TYPES:

VLXE 34 M for tanks with a suction line to the low point of the interstitial space.

VLXE 80 M for tanks with 2 separate chambers leak detection linings for diesel and petrol. The VLXE 80 M with a higher underpressure must be connected to the petrol leak protection lining to ensure that in case of a leak in the area of the chamber wall vapors are drawn in the direction of the Ex leak protection lining and not vice versa.

VLXE 330 M for tanks without a suction line to the low point of the interstitial space, up to 3 meters diameter, and a density of the stored product of <= 1 g/cm3.

VLXE 500 M and VLXE 570 M for tanks with larger diameters and/or higher densities of stored products of 1 g/cm3.

OPTIONAL EQUIPMENT:

8S: with up to 8 probes

Si: service indication (adjustable 1 to 63 months)

TANKS:

  • Horizontal cylindrical tanks with a maximum diameter of 3 meters
  • Pressureless or with slight overpressures of a maximum of 50 mbar through gas recirculation systems at filling stations
  • Underpressure resistance of interstitial space: VLX 34 M > -250 and VLXE 330 M > -700 mbar

STORED PRODUCTS:

Petrol and ethanol-containing fuels, diesel, kerosene, etc. Vapors must be heavier than air!

If the flash point of the liquid to be monitored requires explosion protection measures, the VLXE .. M can only be used on pressureless tanks.

Otherwise the VLXE .. M can also be used on tanks with up to 5 bar overpressure. The international hazardous substances law sets a limit of > 60 °C. National regulations may vary, so Germany > 55 °C.

INSTALLATION:

Outside Ex areas

HOUSING / IP RATE / TEMPERATURE RANGE:

ss-box: stainless steel box / IP 54 / -40 °C .. +60 °C

PNEUMATIC CONNECTIONS:

CF8/6: compression ferrule for copper (CU) pipe 8/6x1mm or compression ferrule ss-CF8/6 for stainless steel (ss) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm

The requirements of the respective documentation must be observed!