TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

VLXE

VLXE
 
For increasing, move mouse over the picture

Vacuum leak detector for pressureless pipes as well as filling and suction lines at filling stations. Its pneumatic part is explosion-proof designed.

TYPES:

VLXE 330 M for pressureless pipes

VLXE 500 M for pressureless pipes and suction lines at filling stations

OPTIONAL EQUIPMENT:

Si: service indication (adjustable 1 to 63 months)

PIPES:

  • Double-walled sufficiently pressure-resistant pipes and fittings made of metal or plastic in factory or on-site construction

CONVEYED PRODUCTS:

Petrol and ethanol-containing fuels, diesel, kerosene, etc. Vapors must be heavier than air!

If the flash point of the liquid to be monitored requires explosion protection measures, the VLXE .. M can only be used on pressureless pipes.

The international hazardous substances law sets a limit of > 60 °C. National regulations may vary, so Germany > 55 °C.

INSTALLATION:

Outside Ex areas, inside ventilated buildings, outdoors

HOUSING / IP RATE / TEMPERATURE RANGE:

ss-box: stainless steel box / IP 54 / -40 °C .. +60 °C

PNEUMATIC CONNECTIONS:

QU8/6: quick union for polyamide (PA) hose 8/6x1mm

CF8/6: compression ferrule for copper (CU) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm

The requirements of the respective documentation must be observed!