TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

DLG

DLG
 
For increasing, move mouse over the picture

Pressure leak detector with gas (nitrogen) as leak detection medium

TYPES:

DLG 280 (P)M, DLG 290 (P)M, DLG 330 (P)M, DLG 450 (P)M, DLG 590 PM, DLG 750 PM, DLG 1000 PM, DLG 1100 PM, DLG 1500 PM, DLG 2300 PM, DLG 2500 PM und DLG 3000 PM

OPTIONAL EQUIPMENT:

P: weatherproof housing

M: digital manometer

Si: service indication (adjustable 1 to 63 months)

(e.g. DLG 280 PMSiLE)

TANKS:

  • Double-walled, horizontal, cylindrical tanks
  • Double-walled tanks with approval or a suitability proven on an individual basis

(!) The pressure resistance of the interstitial space must be ensured for the leak detector used.

STORED PRODUCTS:

Water-polluting liquids. The (possible) explosive vapor-air mixtures (also such ones that can arise through the stored/conveyed liquids in contact with air, humidity, condensation or the materials used) must be classifiable into gas group II A to II B as well as in the temperature code T1 to T3 (T4 after prior consultation with SGB). Examples: petrol, methanol, diesel, chemicals, acid, lye.

INSTALLATION:

Outside Ex areas

HOUSING / IP RATE / TEMPERATURE RANGE:

pl-box: plastic box / IP 30 / -0 °C .. +40 °C

ss-box: stainless steel box / IP 54 / -40 °C .. +60 °C

PNEUMATIC CONNECTIONS:

towards interstitial space:

CF8/6: compression ferrule for copper (CU) pipe 8/6x1mm or

ss-CF8/6 compression ferrule for stainless steel (ss) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm

supply:

CF6/4: compression ferrule for copper (CU) pipe 6/4x1mm or

ss-CF6/4: compression ferrule for stainless steel (ss) pipe 6/4x1mm

The requirements of the respective documentation must be observed!