TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

VL 230

VL 230
 
For increasing, move mouse over the picture

Vacuum leak detector for double-walled horizontal cylindrical tanks, tanks etc.

TYPES:

VL 230

OPTIONAL EQUIPMENT:

FA: level indication

P: weatherproof housing

M: digital manometer

S: service display (preset to 12 months)

Si: service indication (adjustable 1 to 63 months)

(e.g. VL 230 PMSi)

TANKS:

  • Maximum pressure on tank bottom: <= 200 mbar
  • Maximum internal overlay pressure: 500 mbar
  • Underpressure resistance of interstitial space: > -650 mbar

STORED PRODUCTS:

Water-polluting liquids with a flash point > 60 °C (for Germany > 55 °C acc. TRBS and TRGS) where no explosive vapor-air mixtures occur.

INSTALLATION:

Outside Ex areas

HOUSING / IP RATE / TEMPERATURE RANGE:

pl-box: plastic box / IP 30 / -0 °C .. +40 °C

ss-box: stainless steel box / IP 66 / -40 °C .. +60 °C

PNEUMATIC CONNECTIONS:

H4+H6: hose connection for polyvinylchloride (PVC) hose 8/4x2mm or 10/6x2mm (only for pressureless tanks)

QU8/6: quick union for polyamide (PA) hose 8/6x1mm (for tanks with up to 500 mbar overpressure)

CF8/6: compression ferrule for copper (CU) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm (for tanks with up to 500 mbar overpressure)

PP-version: Polypropylen (PP)-design for higher resistance against chemicals

The requirements of the respective documentation must be observed!