TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

Leak Detector VLXE-S 350 M, 100-240VAC, Leak indicating unit for 3 sensors

  • Leak Detector VLXE-S 350 M, 100-240VAC, Leak indicating unit for 3 sensors
    Leak Detector VLXE-S 350 M, 100-240VAC, Leak indicating unit for 3 sensors
     
    For increasing, move mouse over the picture
    leckanzeiger-vlxe-s-350-m-100-240-vac-leckanzeigeeinrichtung-3-sensoren-099553-m.jpg
Article No.
099553
Price
Price on request
Quantity
pcs

Vacuum leak detector explosion protected electronically operating (VLXE-S 350 M), leak indicating unit, without integrated pump (static), for the connection of 3 pressure sensors for the installation outside of any Ex-area.

For one above or underground double-walled tank with max. 3 m height and suction line to the low point of the interstitial space (resistant to negative pressure up to at least 800 millibars).

Display of negative operating pressure and alarm condition for each connected sensor. With central audible alarm and dry relay contact for each sensor for alarm transmission.

power supply: 100-240 VAC | 24 VDC

plastic box (pl-box)

IP rate: IP30