TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

Leak Detector DLR-P 2.0, pul-d, 100-240VAC|24VDC, pl-box, CF8/6

  • Leak Detector DLR-P 2.0, pul-d, 100-240VAC|24VDC, pl-box, CF8/6
    Leak Detector DLR-P 2.0, pul-d, 100-240VAC|24VDC, pl-box, CF8/6
     
    For increasing, move mouse over the picture
    leckanzeiger-rohrleitung-ueberdruck-dlr-p-2-0-messleitung-pulsationsdaempfer-klemmringverschraubung-078120-04-m.jpg
Article No.
078120-04
Price
Price on request
Quantity
pcs

Pressure leak detector pipeline pump (DLR-P) with 2 bar alarm pressure for above and underground double-walled pipes and 3 bar minimum test pressure of the interstitial space

with pulsation damper (pul-d)

for the monitoring of water-polluting liquids whose (possible) explosive vapor-air mixtures (also such ones that can arise through the stored/conveyed liquids in contact with air, humidity, condensation or the materials used) can be classified into gas group II A to II B3 as well as in the temperature code T1 to T3, for example: petrol.

power supply: 100-240 VAC | 24 VDC

plastic box (pl-box)

IP rate: IP30

temperature range: -0 °C .. +40 °C (indoor installation)

pneumatic connection: compression ferrule CF8/6 for copper (CU) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm with support sleeve