Vacuum leak detector explosion protected (VLX 350 SA-Ex), working unit, explosion protected without integrated pump (static), category 2, for the installation in zone 1, weatherproof design,
with 350 mbar alarm pressure
with leak indication unit in plastic box
for the monitoring of water-polluting liquids of those the (possible) explosive vapor-air mixtures (also such ones that can arise through the stored/conveyed liquids in contact with air, humidity, condensation or the materials used) must be classifiable into gas group II A to II C as well as in the temperature code T1 to T6.
power supply: 24 VDC
protection type of housing, indicating unit: IP30
protection type of leak detector (contact manometer): IP65
operating temperature range leak indicating unit: 0 °C to +40 °C
operating temperature range contact manometer: -20 °C to +60 °C