TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

Leak Detector VLXE 500 MSi, 100-240VAC|24VDC, ss-box, CF8/6

  • Leak Detector VLXE 500 MSi, 100-240VAC|24VDC, ss-box, CF8/6
    Leak Detector VLXE 500 MSi, 100-240VAC|24VDC, ss-box, CF8/6
     
    For increasing, move mouse over the picture
    vakuum-leckanzeiger-behaelter-rohrleitung-unterdruck-vlxe-500-msi-edelstahlgehause-manometer-deto-service-indikation-klemmringverschraubung-030500M04Si-m.jpg
Article No.
030500M04Si
Price
Price on request
Quantity
pcs

Vacuum leak detector explosion protected electronically operating (VLXE ..), partially explosion protected with integrated pump, for the installation outside of Ex-areas, weatherproof design,

with 500 mbar alarm pressure

with detonation flame arresters in suction and exhaust line

for one above or underground double-walled tank or for above and underground double-walled pipes

with digital manometer (M)

with service indication (Si) indicates the due and prescribed functional test depending on the set maintenance/service interval (time period adjustable between 1 and 63 months)

for the monitoring of water-polluting liquids of those the (possible) explosive vapor-air mixtures (also such ones that can arise through the stored/conveyed liquids in contact with air, humidity, condensation or the materials used) must be classifiable into gas group II A to II B3 as well as in the temperature code T1 to T3, for example: petrol and ethanol-containing fuels, diesel, kerosene, etc.

Vapors must be heavier than air!

If the flash point of the liquid to be monitored requires explosion protection measures, the VLXE .. M can only be used on pressureless tanks.

Otherwise the VLXE .. M can also be used on tanks or pipes with up to 5 bar overpressure.

The international hazardous substances law sets a limit of > 60 °C. National regulations may vary, so in Germany > 55 °C.

power supply: 100-240 VAC | 24 VDC

stainless steel box (ss-box)

IP rate: IP66

temperature range: -40 °C .. +60 °C

pneumatic connection: compression ferrule CF8/6 for copper (CU) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm with support sleeve