TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

Leak Detector DL 330 PFCM, 100-240VAC|24VDC, ss-box, CF8/6

  • Leak Detector DL 330 PFCM, 100-240VAC|24VDC, ss-box, CF8/6
    Leak Detector DL 330 PFCM, 100-240VAC|24VDC, ss-box, CF8/6
     
    For increasing, move mouse over the picture
    leckanzeiger-behaelter-ueberdruck-dl-330-pfcm-100-240vac-oder-24vdc-edelstahlgehause-filterkontrolle-manometer-klemmringverschraubung-062033P04-m.jpg
Article No.
062033P04
Price
Price on request
Quantity
pcs

Pressure leak detector (DL) with 330 mbar alarm pressure for above and underground double-walled tanks up to max. 3 meter diameter and 500 mbar minimum test pressure of the interstitial space

with weatherproof design (P)

with filter control (FC) visual and audible alarm when drying agent is saturated

with digital manometer (M)

For the monitoring of water-polluting liquids of those the (possible) explosive vapor-air mixtures (also such ones that can arise through the stored/conveyed liquids in contact with air, humidity, condensation or the materials used) must be classifiable into gas group II A to II B3 as well as in the temperature code T1 to T3, for example: petrol.

power supply: 100-240 VAC | 24 VDC

stainless steel box (ss-box)

IP rate: IP66

temperature range: -40 °C .. +60 °C

pneumatic connection: compression ferrule CF8/6 for copper (CU) pipe 8/6x1mm or polyamide (PA) hose 8/6x1mm with support sleeve