TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

Leak Detector VLXE-SAB T34 / T80 (5/1), 100-240VAC, st-box, QU8/6

  • Leak Detector VLXE-SAB T34 / T80 (5/1), 100-240VAC, st-box, QU8/6
    Leak Detector VLXE-SAB T34 / T80 (5/1), 100-240VAC, st-box, QU8/6
     
    For increasing, move mouse over the picture
    leckanzeiger-kombination-mehrkammertanks-tankstellen-ueberdruck-vlxe-sab-t34-t80-stahlgehause-quickverschraubung-039B5C1-07-m.jpg
Article No.
039B5C1-07
Price
Price on request
Quantity
pcs

Ex vacuum leak detector VLXE-SAB T34 / T80 (5/1)  in a stand alone box for the installation outside ex areas, or in areas in which an Ex-zone does not exceed a height of 1 meter above ground with
34 mbar alarm underpressure for 5 underground doublewalled tanks (T) with
-500 mbar minimum underpressure suitability for the interstitial space

80 mbar alarm underpressure for 1 underground doublewalled tanks (T) with

-500 mbar minimum underpressure suitability for the interstitial space

For the monitoring of water-polluting liquids whose (possible) explosive vapor-air mixtures (also those that can be formed through the stored/conveyed liquids in contact with air, humidity, condensation, or the materials used) must be classifiable into gas group  II A to II B3 as well as in the temperature code T1 to T4, for example: petrol.
Digital pressure display for each interstitial space in the inner part of housing for comfortable maintenance
temperature range: -20 °C .. +60 °C
power supply: 100-240 VAC, 50/60 Hz, power input: 125 W .. 250 W
painted steel box (st-box)
IP rate: IP54
pneumatic connection: quick union QU8/6 for polyamide (PA) hose 8/6x1mm