TOP
We use cookies on our websites.
If you continue browsing, we’ll assume that you agree.
Allow the following cookies
Show
Cookie Name Description
allowedCookiesCategoriesDefines which cookies categories may be accepted.
Exposure time: 1 day.
cookies-info-readThe flag, that this information about the cookies was read. If not empty then this popup will be hidden.
Exposure time: 1 day.
ga-disabledThe "Opt-Out" cookie for the deactivating of Google Analytics.
Exposure time: 1 day.
navigationTree_a_clickedSaves which menu item was clicked at last.
Exposure time: 1 day.
PHPSESSIDContains the session identification string, which for the shop functionality is extremely required.
Exposure time: until end of this session.
tab_cookie_tabsArticleDetails_*Contains the information about which text tab by the article details view was selected at last.
Exposure time: 1 day.
Show
Cookie Name Description
_ga*Providers: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
_gatProvider: Google Analytics.
Used by Google Analytics to throttle request rate.
Exposure time: 2 years.
_gidProviders: Google Analytics, Google Tag Manager.
Registers a unique ID that is used to generate statistical data on how the visitor uses the website.
Exposure time: 2 years.
Show
Cookie Name Description
social-c1Social description 1
line 2
social-c2Social description 2

Leckdetektor DLR-G 2 MSi, 100-240VAC|24VDC, pl-box, FU8/6

  • Leckdetektor DLR-G 2 MSi, 100-240VAC|24VDC, pl-box, FU8/6
    Leckdetektor DLR-G 2 MSi, 100-240VAC|24VDC, pl-box, FU8/6
     
    For increasing, move mouse over the picture
    leckanzeiger-rohrleitung-stickstoff-ueberdruck-dlrg-2-msi-manometer-serviceindikation-quickverschraubung-073020M07Si-m.jpg
Article No.
073020M09Si
Price
Price on request
Quantity
pcs

Pressure leak detector pipeline gas (DLR-G) based on nitrogen with 2 bar alarm pressure and 4,5 bar minimum test pressure of the interstitial space

for above and underground double-walled pipes

with digital manometer (M)

with service indication (Si) indicates the due and prescribed functional test depending on the set maintenance/service interval (time period adjustable between 1 and 63 months)

For the monitoring of water-polluting liquids, whose (possible) explosive vapor-air mixtures (also those that can be formed through the stored/conveyed liquids in contact with air, humidity, condensation or the materials used) must be classifiable into gas group II A to II C as well as in the temperature code T1 to T4. In case compressed air is used as leak detection medium, restrictions regarding explosion protection and permeation of the inner pipe wall must be observed..

power supply: 100-240 VAC | 24 VDC

IP rate: IP30

temperature range: -0 °C .. +40 °C (indoor installation)

pneumatic connection: flared union FU6/4 for copper (CU) pipe 6/4x1mm